Sign In | Join Free | My autochinanet.com
China Beijing Tonghe Testing Machine Co., ltd logo
Beijing Tonghe Testing Machine Co., ltd
WE OFFER ONLY WHAT SUITS YOU BEST!
Verified Supplier

1 Years

Home > Differential Scanning Calorimeter >

User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis

Beijing Tonghe Testing Machine Co., ltd
Trust Seal
Verified Supplier
Credit Check
Supplier Assessment
Contact Now

User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis

  • 1
  • 2

Brand Name : TH

Model Number : DSC-ZS5

Certification : ISO9001 , CE

Place of Origin : BEIJING, CHINA

MOQ : 1 set

Payment Terms : L/C,D/A,D/P,T/T,Western Union

Supply Ability : 20 sets per month

Delivery Time : 10~15 work days

Packaging Details : Standard export wooden box

Product name : User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis

Temperature resolution : 0.01 ℃

Heating rate : 0.1~40℃/min

Cooling rate : 0.1~20℃/min

DSC range : 0 ~ + 500 mw

DSC resolution : 0.01 mW

DSC sensitivity : 0.01 mW

Temperature control mode : Heating, cooling, constant temperature

Contact Now

User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis



Summary:

This touch-screen DSC instrument is specially developed for the test of oxidation induction time of polymer materials, supporting user-friendly one-key operation and fully automatic control via the dedicated software.

It is in full compliance with the following standards:
GB/T 19466.2-2009 / ISO 11357-2:1999
GB/T 19466.3-2009 / ISO 11357-3:1999
GB/T 19466.6-2009 / ISO 11357-6:1999


Features:

1.The industrial-grade wide-screen touch panel presents comprehensive operating data, including set temperature, sample temperature, oxygen flow rate, nitrogen flow rate, differential thermal signal and various working state indicators.


2.It is equipped with a USB communication port, featuring strong compatibility, stable signal transmission and an automatic reconnection function.

3.The furnace chamber boasts a compact structure, with adjustable heating and cooling rates.

4.The upgraded assembly adopts a mechanical fixing scheme, which completely avoids interference from internal colloidal substances inside the furnace to the differential thermal signal.

5.The furnace is heated by electric heating wires and cooled by circulating cooling water with compressor refrigeration, presenting a compact and miniaturized structure.

6.Dual temperature probes ensure high repeatability of sample temperature measurement, and dedicated temperature control technology is adopted to adjust the furnace wall temperature to match the preset sample temperature.

7.The gas flowmeter realizes automatic switching between dual gas channels, with fast switching speed and short stabilization duration.

8.A standard sample is supplied for convenient calibration of the temperature coefficient and enthalpy coefficient.

9.The software supports all screen resolutions and automatically adapts the curve display mode to the monitor size. It is compatible with laptops and desktop computers, and supports operating systems including Win2000, XP, Vista, Win7, Win8 and Win10.

10.It allows users to edit the instrument’s operating modes based on actual demands to achieve full automation of testing procedures. The software provides dozens of functional instructions, enabling users to flexibly combine and save instructions according to their test steps, simplifying complex operations into one-key execution.

11.The fully enclosed support structure prevents foreign objects from falling into and contaminating the furnace chamber, thus lowering the maintenance rate.


Parameters:

Temperature range 0℃~500℃
Temperature resolution 0.01℃
Heating rate 0.1~40℃/min
Cooling rate 0.1~20℃/min
Calorimetric resolution 100%.
Constant temperature 5℃~500℃
Duration of constant temperature The duration is recommended to be less than 24 hours.
Temperature control mode Heating, cooling, constant temperature
DSC range 0~±500mW
DSC resolution 0.01mW
DSC sensitivity 0.01mW
Working power AC 220V 50Hz 300W or other
Atmosphere control gas Two-channel gas control by automatic controlled (e.g. nitrogen and oxygen)
Gas flow 0-200mL/min
Gas pressure 0.2MPa
Gas flow accuracy 0.2mL/min
Crucible Aluminium crucible Φ6.6*3mm (Diameter * High)
Calibration standard with standard material (indium, tin, zinc)
Data interface Standard USB interface
Display mode 7-inch touch screen
Output mode computer and printer


Configuration list:

DSC machine 1 set
Aluminium crucibles 300 pieces
Power cords and USB cable Each one
CD (contains software and operations video) One
Soft-key One
Oxygen airway and nitrogen airway Each 5m
Operation manual One
Standard sample(contains Indium, tin, zinc) Each one
Tweezer and medicine spoon Each one
Custom pressure reducing valve joint and quick joint Two
Fused glass fuses Four
External circulation thermostat sink One
Water pipe One


Furnace bracket:

User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis


Software screenshots:

User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis


User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis

User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis

User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis


Product Tags:

touch screen differential scanning calorimeter

      

polymer oxidation induction period analyzer

      

thermal analysis differential scanning calorimeter

      
China User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis factory

User Friendly Differential Scanning Calorimeter with Touch Screen Interface for Polymer Oxidation Induction Period and Thermal Analysis Images

Inquiry Cart 0